Accessing internal controls
Unscrew the pressure sensor cord and pull straight out to remove it. Remove the nut on the Psi Sensor connector using a 10mm wrench.
Remove the black endcap by unscrewing the 4 screws. Screws are self-retaining in the endcap so loosen one halfway until you feel resistance then move to the next. Continue until they are fully removed.
Slide the circuit board out 1/2” to see the dip switch and settings buttons.
Changing the node address
Senders ship with the node number set to 1. Each device must be set to a different number for the display to recognize them separately.
Use the address dip switch to change the address if the sender is a 2nd or 3rd unit.
Tip: Use a pointy object like a pen to flip switches easier.
Node address options:
Node 1 - selector 1 in up position, selector 2 down
Node 2 - selector 1 in down position, selector 2 up
Node 3 - selector 1 in up position, selector 2 up
Address zero (both selectors down) should not be used. Node 0 will not show on the display.