Change the node address

For using two or more senders

Accessing internal controls

Unscrew the pressure sensor cord and pull straight out to remove it. Remove the nut on the Psi Sensor connector using a 10mm wrench.


  1. Remove the black endcap by unscrewing the 4 screws.  Screws are self-retaining in the endcap so loosen one halfway until you feel resistance then move to the next.  Continue until they are fully removed.

  2. Slide the circuit board out 1/2” to see the dip switch and settings buttons.


Changing the node address

Senders ship with the node number set to 1. Each device must be set to a different number for the display to recognize them separately.


Use the address dip switch to change the address if  the sender is a 2nd or 3rd unit.  


Tip: Use a pointy object like a pen to flip switches easier.


Node address options:

  • Node 1 - selector 1 in up position, selector 2 down

  • Node 2 - selector 1 in down position, selector 2 up

  • Node 3 - selector 1 in up position, selector 2 up


Address zero (both selectors down) should not be used. Node 0 will not show on the display. 